For our Christmas opening times and delivery advice please click here

Search

    Product Details

    New technology from Europe to treat sports injuries, back pain, osteoarthritis,Tendinopathy, ligament injury, damaged muscles, maintain athletes in top condition prior to sport & facilitate recovery.

    \


    \

    £6995 plus VAT introductory price

    \

    \

    Usually £8995 plus VAT

    TECAR I-TECH AR system

    \

    TECAR radio-frequency treatment

    \

    It's a good electrotherapy treatment to combine with manual therapy & rehabilitation.

    \

     

    \

    Who uses TECAR Therapy ?

    \

     

    \

    •Used by Olympic champions worldwide

    \

    •Used in Orthopaedic & pain clinics

    \

    •Used by physiotherapists, osteopaths & chiropractors

    \

    •Used in Sports medicine clinics by

    \

    sports physicians  

    \

     

    \

     MAIN TECHNICAL FEATURES:

    \

    •          Power supply 220-240 V 50/60 Hz

    \

    •          Power consumption 100W

    \

    •          Working maximum power consumption 120W

    \

    •          Peak power consumption 200W

    \

    •          Peak voltage:

    \

    •          Resistive 105V max

    \

    •          Capacitive 300V max

    \

    •          Peak current:

    \

    •          Resistive 1.3 A max

    \

    •          Capacitive 500 mA max

    \

    •          Carrier frequency 455 kHz

    \

    •          6 electrodes (3 resistive +3 capacitive)

    \

    •          Adjustable power  0-100%

    \

    •          Touch screen graphic display

    \

    •          Preadjusted programs, free memories, Smart Card

    \

     

    \

    The new I-TECH.AR TECAR resistive/capacitive radio frequency is modern and high performance device that is very easy to use by the professional user once 4 hours training is given.

    \

    Preadjusted programs facilitate the use of device from the start. Moreover the device offers the possibility to set the parameters (power, time therapy, capacitive/resistive modes) according to therapeutic needs.

    \

    TECAR I-TECH.AR is provided with SMART CARD to allow the memorization of customized programs. In this way patient protocols are easily consulted by therapists at any time

    \

    TECAR I-TECH.AR is equipped with a wide graphic display to show therapy parameters and different working modes. Menu can be easily scrolled by a comfortable control knob.

    \

    TECAR I-TECH.AR is provided with a conductive cream indicated for diathermic treatment and with the following electrodes:

    \

    •          2 electrodes 30mm diameter (1 resistive+1 capacitive) with effective working area di 7.1 cm²

    \

    •          2 electrodes 50mm diameter (1 resistive+1 capacitive) with effective working area di 19.6 cm²

    \

    •          2 electrodes 70mm diameter (1 resistive+1 capacitive) with effective working area di 38.5 cm²

    \

    Auto adhesive and soft plates are available as accessories with the following size:

    \

    •          217 x 105 mm (active surface 136 cm²)

    \

    •          150 x 105 mm (active surface 82 cm²)

    \

    •          88 x 74 mm (active surface 36 cm²)

    \

    TECAR I-TECH.AR is a medical device with European CE0476 certificated. The device must be used only by authorised personnel in hospitals and clinics

    \

    Muscle-skeletal pathologies TECAR Therapy (acronym meaning Capacitive and Resistive Energy Transfer), is a technique that stimulates the physiological healing process by accelerating the recovery time of motor function. TECAR can treat Acute injuries with low energy producing an interchange of tissue fluid and improved permeability of cell membrane without heat.

    \

    TECAR in medium to high energy settings can produce diathermy.This stimulates tissues endogenously causing heat production through the interaction of electromagnetic radio frequency field in an AC current at 455KZ. The heat is produced in a uniform controlled way. The electromagnetic interaction results in a ionic flow and consequently increases blood flow in the treated area. This process stimulates endogenous substances release (in particular cortisol and endorphins) that are indispensable to reduce inflammations, pain and edemas.

    \

    Main treatments:

    \

    •          Chondropathy

    \

    •          Coxarthrosis

    \

    •          Lumbalgy, pubalgy and acute/chronic pain

    \

    •          Muscle sprains

    \

    •          Muscle contractures

    \

    •          Articular rehabilitations

    \

    •          Mialgias

    \

    •          Cervicalgy

    \

    •          Periarthritis

    \

    •          Epicondylitis/epitrochleitis

    \

    •          Carpal tunnel syndrome

    \

    •          Rizarthrosis

    \

    •          Coxalgy

    \

    •          Gonarthrosis

    \

    •          Patellar and Achilles tendonitis 

    \

    •          Tibia-tarsica strain

    \

    •          Bursitis

    \

    •          Plantar fasciitis/metatarsalgia

    \

    •          Osteoarticular pathologies

    \

    •          Skeletal-muscle pathologies

    \

     

    \

    ACCESSORIES

    \

    •          Trolley with 3 shelves and 1 power socket

    \

    •          Stainless steel support for resistive and capacitive electrodes

    \

     

    \

    •          Support for diathermy cream dispenser 1000 ml

    Tecar Therapy System

    EL1111

    • CODE
      Title
      Stock
      QTY
      Price
      EL1111

      Tecar Therapy System

      Tecar Therapy System
      x
      Out of Stock
      Out of Stock
    These items are subject to VAT
    Sub Total

    Product Details

    New technology from Europe to treat sports injuries, back pain, osteoarthritis,Tendinopathy, ligament injury, damaged muscles, maintain athletes in top condition prior to sport & facilitate recovery.

    \


    \

    £6995 plus VAT introductory price

    \

    \

    Usually £8995 plus VAT

    TECAR I-TECH AR system

    \

    TECAR radio-frequency treatment

    \

    It's a good electrotherapy treatment to combine with manual therapy & rehabilitation.

    \

     

    \

    Who uses TECAR Therapy ?

    \

     

    \

    •Used by Olympic champions worldwide

    \

    •Used in Orthopaedic & pain clinics

    \

    •Used by physiotherapists, osteopaths & chiropractors

    \

    •Used in Sports medicine clinics by

    \

    sports physicians  

    \

     

    \

     MAIN TECHNICAL FEATURES:

    \

    •          Power supply 220-240 V 50/60 Hz

    \

    •          Power consumption 100W

    \

    •          Working maximum power consumption 120W

    \

    •          Peak power consumption 200W

    \

    •          Peak voltage:

    \

    •          Resistive 105V max

    \

    •          Capacitive 300V max

    \

    •          Peak current:

    \

    •          Resistive 1.3 A max

    \

    •          Capacitive 500 mA max

    \

    •          Carrier frequency 455 kHz

    \

    •          6 electrodes (3 resistive +3 capacitive)

    \

    •          Adjustable power  0-100%

    \

    •          Touch screen graphic display

    \

    •          Preadjusted programs, free memories, Smart Card

    \

     

    \

    The new I-TECH.AR TECAR resistive/capacitive radio frequency is modern and high performance device that is very easy to use by the professional user once 4 hours training is given.

    \

    Preadjusted programs facilitate the use of device from the start. Moreover the device offers the possibility to set the parameters (power, time therapy, capacitive/resistive modes) according to therapeutic needs.

    \

    TECAR I-TECH.AR is provided with SMART CARD to allow the memorization of customized programs. In this way patient protocols are easily consulted by therapists at any time

    \

    TECAR I-TECH.AR is equipped with a wide graphic display to show therapy parameters and different working modes. Menu can be easily scrolled by a comfortable control knob.

    \

    TECAR I-TECH.AR is provided with a conductive cream indicated for diathermic treatment and with the following electrodes:

    \

    •          2 electrodes 30mm diameter (1 resistive+1 capacitive) with effective working area di 7.1 cm²

    \

    •          2 electrodes 50mm diameter (1 resistive+1 capacitive) with effective working area di 19.6 cm²

    \

    •          2 electrodes 70mm diameter (1 resistive+1 capacitive) with effective working area di 38.5 cm²

    \

    Auto adhesive and soft plates are available as accessories with the following size:

    \

    •          217 x 105 mm (active surface 136 cm²)

    \

    •          150 x 105 mm (active surface 82 cm²)

    \

    •          88 x 74 mm (active surface 36 cm²)

    \

    TECAR I-TECH.AR is a medical device with European CE0476 certificated. The device must be used only by authorised personnel in hospitals and clinics

    \

    Muscle-skeletal pathologies TECAR Therapy (acronym meaning Capacitive and Resistive Energy Transfer), is a technique that stimulates the physiological healing process by accelerating the recovery time of motor function. TECAR can treat Acute injuries with low energy producing an interchange of tissue fluid and improved permeability of cell membrane without heat.

    \

    TECAR in medium to high energy settings can produce diathermy.This stimulates tissues endogenously causing heat production through the interaction of electromagnetic radio frequency field in an AC current at 455KZ. The heat is produced in a uniform controlled way. The electromagnetic interaction results in a ionic flow and consequently increases blood flow in the treated area. This process stimulates endogenous substances release (in particular cortisol and endorphins) that are indispensable to reduce inflammations, pain and edemas.

    \

    Main treatments:

    \

    •          Chondropathy

    \

    •          Coxarthrosis

    \

    •          Lumbalgy, pubalgy and acute/chronic pain

    \

    •          Muscle sprains

    \

    •          Muscle contractures

    \

    •          Articular rehabilitations

    \

    •          Mialgias

    \

    •          Cervicalgy

    \

    •          Periarthritis

    \

    •          Epicondylitis/epitrochleitis

    \

    •          Carpal tunnel syndrome

    \

    •          Rizarthrosis

    \

    •          Coxalgy

    \

    •          Gonarthrosis

    \

    •          Patellar and Achilles tendonitis 

    \

    •          Tibia-tarsica strain

    \

    •          Bursitis

    \

    •          Plantar fasciitis/metatarsalgia

    \

    •          Osteoarticular pathologies

    \

    •          Skeletal-muscle pathologies

    \

     

    \

    ACCESSORIES

    \

    •          Trolley with 3 shelves and 1 power socket

    \

    •          Stainless steel support for resistive and capacitive electrodes

    \

     

    \

    •          Support for diathermy cream dispenser 1000 ml

    Search

      , as a privileged user, you are able to simulate the login of other customers.

      Nothing found!
      Search results:
      //physiosupplies.co.uk/cdn/shop/t/7/assets/asc_sort.gif?v=92375865483100590141725330000
      //physiosupplies.co.uk/cdn/shop/t/7/assets/desc_sort.gif?v=117534751354829613561725330000
      //physiosupplies.co.uk/cdn/shop/t/7/assets/no_sort.gif?v=15794768332898334801725330000
      Customer code Account name Phone Street Suburb Postcode Login

      You are browsing as

      Code:
      -
      Phone:
      -
      Email:
      -
      Mailing Address:
      -
      Delivery Address:
      -
      Status:
      -
      Sales Rep:
      -
      Sales Rep Phone:
      -
      Web Invoices:
      -
      Web Statements:
      -